102
Dran-View 6 User Guide
10.10.2. Use for DFT Chart selection fine-tuning
Use for
DFT fine
tuning
Select a Waveform chart with a waveform event visible, and select the command
Insert > DFT Chart from the toolbar or from the menu (or right-click on the chart
and select Insert DFT Chart). The newly created DFT is now connected to the
waveform chart and will display the DFT analysis for the current event range.
Now activate the Area Marker Tool and select a range of waveform cycles. When
you release the pointer button, you will see the DFT-Chart updates. It will also
show the DFT contents of the selected waveform range. The Area Marker selection
in the waveform chart overrides the current event range for DFT calculations.
When selecting an area in a Waveforms/Details chart, the area marker will adjust
itself to the nearest full waveform cycle(s), unless you have selected the Free
Selection option (described below). This is done so you can see the true range used
for DFT calculations. This checkbox is also available in the upper right corner of
the waveform chart along with information about selected waveform sample points.
10.10.3. Use for Phasor selection fine-tuning
Use for
Phasor fine
tuning
If you have a Phasor located within a frame of Waveform chart, the phasor is
connected to that chart. Normally the phasor shows the phase angles for the
selected event, but with an Area Marker selection in that Waveform Chart, this
behavior is overridden and the Area Marker rules the calculation of the Phasor.
10.10.4. Use for Statistics Table selection fine-tuning
Use for
statistics
tables fine
tuning
If you add a Statistics table to the Timeplot Chart (locate it within the frame of the
chart), it normally displays information gathered within the borders of the current
X-axis zoom. However with an Area Marker selection in that Timeplot Chart, this
behavior is overridden and the Area Marker rules the calculation of the Statistics
table.