Dranetz Xplorer Guide de l'utilisateur Page 52

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 290
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 51
3-10
User Specified Frequency Meter Tab
User Specified Frequency Meter Tab
User frequency
meter list
Voltage and current harmonics for each phase and neutral channel can be metered under
the User Specified Frequency tab. The value fields are initially not specified to allow
users to choose the numbers or the range of harmonic frequencies to meter. The system
simultaneously measures voltage and current so that harmonic power can be obtained.
Whereas harmonic summary values include harmonics up to the 127th in Standard
Power Quality mode, individual harmonics displayed on the instrument are only
available up to the 60th.
User Frequency Tab Parameter Name Label
Vo lta g e
(for A, B, C, D)
User Selected Voltage Harmonic 1 User 1
User Selected Voltage Harmonic 2 User 2
User Selected Voltage Harmonic 3 User 3
User Selected Voltage Harmonic 4 User 4
Current
(for A, B, C, D)
User Selected Current Harmonic 1 User 1
User Selected Current Harmonic 2 User 2
User Selected Current Harmonic 3 User 3
User Selected Current Harmonic 4 User 4
MARK321