6-13
CH 6/ Advanced Setup Options
Waveform Capture
Trigger channel
setup
The PowerVisa allows users to set the trigger channels/parameters for waveform
capture.
Action... Result...
STEP 1: The checked fields show
the channels that will have
waveforms recorded should a
trigger occur. This cross-trigger
function prevents recording of
meaningless data from unused
(disabled) channels.
• Press to select the Volts or
Amps channel matrix. The
channels selected for the matrix
will be displayed. Each matrix
assigns a different group to
trigger and save. See NOTE
describing the characteristics of
each channel matrix.
Check/Uncheck a channel field
to enable/disable channel for
waveform capture. Proceed to
Step 2.
• Press OK to accept new trigger
channel settings and return to
Advanced Options menu.
• Press Cancel to retain previous
trigger channel settings and
return to Advanced Options
menu.
• Press Group A B C to set
identical matrix for Channels
A, B and C.
MARK112_207
NOTE:
First row channel selection: When individual
Volts (V
A
, V
B
, V
C
, V
D
) trigger, save waveform
data for the checked channels under “Saved
Waveforms”.
Second row channel selection: When Amps (I
A
,
I
B
, I
C
, I
D
) trigger, save waveform data for the
checked channels under “Saved Waveforms”.
Third row channel selection: When Volts phase-
to-phase settings (V
A-B
, V
B-C
, V
C-A
) trigger,
save waveform data for the checked channels
under “Saved Waveforms”.
STEP 2: Depending on the matrix
selected, press to check/uncheck
the trigger channel for waveform
capture.
• Press Clear to reset channel
matrix. The previous channel
settings will be cleared.
MARK112_208